Page 1 - Installation Guide

AsantéHub 2072 NetworkManagement ModuleInstallation Guide

Page 2

Page 9 The Front Panel Table 2 identifies the NMM front panel components and explains the function of each. It also lists LED interpretations where ap

Page 3

Page 10 AsantéHub 2072 Network Management Module Installation Guide Hub Status LEDs(bottom row of 8 LEDs per segment)Provides warning and packet coll

Page 4 - Tell Us What You

Page 11 The Front Panel Segment 2 LED Lights to indicate that the module is currently on Segment 2 of the backplane. If both Segment LEDs are off, th

Page 5 - Introducing the

Page 12AsantéHub 2072 Network Management Module Installation GuideCableConnections toOther DevicesThe NMM’s front panel has two connections (out-of-ba

Page 6

Page 13Cable Connections to Other Devices∆ If you are managing only one hub, set DIPSwitch 1 DOWN (END). 5Set DIP Switch 2 DOWN (SETUP) on all hubs.6I

Page 7

Page 14AsantéHub 2072 Network Management Module Installation GuideMaximum cable length between the AMS and the hub is 100 meters.Figure 5 Using an AMS

Page 8 - Installation

Page 15Cable Connections to Other DevicesIn the first Out-of-Band configuration, the AsantéView Manage-ment Station (AMS) is connected to a hub using on

Page 9

Page 16AsantéHub 2072 Network Management Module Installation GuideThe fourth configuration connects a terminal to an individual hub using the RS232 con

Page 10 - The Front Panel

Page 17Cable Connections to Other DevicesTo connect the hub to a modem, do the following:1Connect the modem only to the end hub.2Set DIP Switch 2 UP f

Page 11 - Name Function

Page 18AsantéHub 2072 Network Management Module Installation Guide1Connect a straight-through RS232 cable to the RS232 connector on the NMM.Figure 9 s

Page 12

AsantéHub 2072NetworkManagementModule InstallationGuide • Introducing the Network Management Module on page 4• Installation on page 6• The Front Pane

Page 13 - Out-of-Band Daisy-Chain

Page 19Using AsantéTermUsing AsantéTerm AsantéTerm, provided with AsantéView In-Band and Out-of-Band, can be used to interrogate and program an Asanté

Page 14 - Management Station to

Page 20AsantéHub 2072 Network Management Module Installation GuideFigure 12 Asanté Remote Management System Main Menu using AsantéTerm

Page 15 - Settings

Page 21Using TelnetUsing Telnet You can use Telnet to interrogate and program an AH2072 NMM NMM with a NetStacker hub or AsantéHub 2072. You can do th

Page 16

Page 22AsantéHub 2072 Network Management Module Installation GuideCopy the files to the AMS Images folder on the Macintosh. On the PC, copy the files to

Page 17 - Connecting a Modem to

Page 23Using TelnetFigure 14 Sample Telnet Session Dialog4Click the OK button. Figure 15 shows the Asanté Remote Management System Main Menu that appe

Page 18 - Management Port

Page 24AsantéHub 2072 Network Management Module Installation GuideUsing the AsantéRemoteManagementSystemThis section contains:❏ General guidelines for

Page 19 - AH2072NMM

Page 25Using the Asanté Remote Management SystemAsanté RemoteManagement SystemMenu TutorialThe following short tutorial navigates through some of the

Page 20 - Using AsantéTerm

Page 26AsantéHub 2072 Network Management Module Installation GuideFigure 17 Example General Configuration ScreenThe example shows “Office Hub” as the cu

Page 21 - AsantéTerm

Page 27Using the Asanté Remote Management SystemFigure 18 Enter Password Prompt4Type the password Asante (the password is case-sensi-tive) and press r

Page 22 - Using Telnet

Page 28AsantéHub 2072 Network Management Module Installation Guide5Type a from the Configuration menu. This takes you to the System Administration Info

Page 23 - Image Code

Page 2 AsantéHub 2072 Network Management Module Installation Guide Askingfor Assistance Asanté Technical Support To contact Asanté Technical Support:

Page 24

Page 29Using the Asanté Remote Management SystemFigure 21 Enter Hub Name Prompt7Type Office Hub 2072 (or a different name if you wish) and press return

Page 25 - Management

Page 30AsantéHub 2072 Network Management Module Installation GuideFigure 22 System Administration Information Menu Showing New Hub Name8Press q to ret

Page 26 - Menu Tutorial

Page 31Configuration MenuConfigurationMenuThis section shows you how to access the Asanté Remote Manage-ment System Configuration menu and then describes

Page 27

Page 32AsantéHub 2072 Network Management Module Installation GuideSystem Administration InformationUse to enter and transmit text strings defining the

Page 28 - Figure 19 Configuration Menu

Page 33Configuration MenuGroup ParametersUse to assign to a segment or isolate, meaning assign to no seg-ment, a group. (A group is defined as all of th

Page 29

Page 34AsantéHub 2072 Network Management Module Installation GuidePressing a sets the node summary aging time, which is the amount of time the hub sto

Page 30

Page 35Configuration MenuReset SystemUse to send an immediate Reset command to the hub, causing a soft reset. Terminal communication is lost briefly, th

Page 31 - Quit from the File menu. Or

Page 36AsantéHub 2072 Network Management Module Installation GuideFigure 24 Configuration Menu example3Type c for Console Password. The Command> lin

Page 32 - Configuration

Page 37Configuration Menu5Type the new password a second time and press return. The new password is sent to the hub and you’re taken back to the Configu

Page 33 - ❏ Authentication trap

Page 38AsantéHub 2072 Network Management Module Installation GuideSegment Control The AsantéHub 2072 and NetStacker hub provide two discrete network s

Page 34 - Configuration Menu

Page 3 Tell Us What You Think Tell Us What YouThink There’s always room for improvement and Asanté Technologies is interested in your comments and su

Page 35

Page 39Segment ControlSetting Segment ControlManuallyThis section explains how to first select a module for a segment change and then perform the actua

Page 36

Page 40AsantéHub 2072 Network Management Module Installation Guide3Press the Change Segment button repeatedly until you have chosen the segment you wa

Page 37 - Type c for Console Password

Page 41Technical SpecificationsTechnicalSpecificationsPhysical Dimensions:17” x 0.9” x 12” Weight: Approximately 2 lbs. (2.73 kg)Non-volatile Program Me

Page 38

Index i Index Index Symbols <Cmd> column 24 Numerics 2072h.cfg configuration file 21, 322072huxx.17x image file 21 A aging time 34Alignment Err

Page 39 - Segmenting the Network

Index ii Index password 34, 35port parameters 34segments 10, 39 defining hub IP address 32dial string 32, 34DIP Switches AMS PORT/SETUP 10settings co

Page 40 - Manually

Index iii Index MIB AsantéHub 2072 5support 4 Microsoft Windows and the NMM 4MJLPs 33modules, isolating 40MSG LED 9Multicast 33 N NCSA/BYU Telnet ver

Page 41 - Isolating Modules from

Index iv Index segmenting the network, example 38segments, LEDs while changing 40Select Next Group menu item 33Select Slot button 10, 38, 39serial in

Page 42 - Specifications

Page 4 AsantéHub 2072 Network Management Module Installation Guide Introducing theNetworkManagementModule The Asanté 2072 Network Management Module (

Page 43

Page 5 Introducing the Network Management Module With the NMM’s Segment Control buttons, you can manually iso-late any AH 2072 NMM or NetStacker mod

Page 44 - Out-of-Band daisychain 12

Page 6 AsantéHub 2072 Network Management Module Installation Guide Installation The NMM installation consists of: ❏ Grounding yourself ❏ Checking pa

Page 45

Page 7 Installation 2 Align the module with the inside edges of the card guides on any available slot in the chassis. Gently slide the module in unti

Page 46

Page 8 AsantéHub 2072 Network Management Module Installation Guide The Front Panel The NMM front panel has several LEDs, ports, connectors, and switc