To mount the switch onto an equipment rack:
1. Place the switch on a flat, stable surface.
2. Locate a rack-mounting bracket (supplied) and place it over the
mounting holes on one side of the unit.
3. Use the screws (supplied) to secure the bracket (with a Phillips
screwdriver).
4. Repeat the two previous steps
on the other side of the unit.
5. Place the switch in the equip-
ment rack.
6. Secure the switch by securing
its mounting brackets onto the
equipment rack.
Important! Make sure the unit is
supported until all of the mounting screws for each bracket are se-
cured to the equipment rack. Failure to do so could cause the unit to
fall, which may result in personal injury or damage to the unit.
2.7.2 Equipment Rack Guidelines
Size: 17.1 x 10.1 x 1.6 inches (IC35516-T)
17.5 x 14.0 x 2.6 inches (IC35516-G)
Ventilation: Ensure that the rack is installed in a room in
which the temperature remains below 40° C (104° F). Be sure
that no obstructions, such as other equipment or cables,
block airflow to or from the vents.
Clearance: In addition to providing clearance for ventilation, ensure
that adequate clearance for servicing the switch from the front ex-
ists.
2.7.3 Free-Standing/Desktop Placement
The switch has rubber feet for the bottom of the case that allow for se-
cure, free-standing placement of the unit.
Follow the steps below for free-standing/desktop placement:
1. Attach the rubber pads (supplied) to the bottom of each corner of
the unit.
2. Place the unit on a flat, stable surface.
3. Make sure enough ventilation space between the switch and sur-
rounding walls or objects exists.