338 Asanté IntraCore 36000 Series
Default
Disabled
Command Mode
Global Configuration
Usage Guidelines
The time acquired from time servers is used to record accurate dates and times for log events. Without
SNTP, the switch only records the time starting from the factory default set at the last bootup (For example,
00:00:00, Jan. 1, 2001).
This command enables client time requests to time servers specified via the sntp servers command. It
issues time synchronization requests based on the interval set via the sntp poll command.
The SNTP time query method is set to client mode when the first sntp client command is issued. If the sntp
broadcast client command is issued, then the no sntp broadcast client command must be used to return the
switch to SNTP client mode.
Example
The following is sample output from the sntp client command.
Console(config)#sntp server 10.1.0.19
Console(config)#sntp poll 60
Console(config)#sntp client
Console(config)#end
Console#show sntp
Current time: Jul 10 02:52:44 2003
Poll interval: 60
Current mode: unicast
Console#
Related Commands
sntp server
sntp poll
sntp broadcast client
show sntp
16.209 sntp poll
This command sets the interval between sending time requests when the switch is set to SNTP client mode.
Use the no form to restore to the default.
Syntax Description
sntp poll seconds
no sntp poll